Maintenance of a horizontal sterilizer?

This is the title h1 placeholder text


Summary: Products like horizontal sterilizers are basically used in industrial fields. Most of us haven't seen or heard of them. You could say they are not very common in life, but they also play an irreplaceable role in the industrial sector. So, when using them, the first thing we need to understand is the maintenance of the horizontal sterilizer. Let's learn about it together.

Horizontal sterilizers and similar equipment are mostly industrial products, most of us haven't seen or heard of them, you could say they are not very common in life, but they also play an irreplaceable role in the industrial sector. So, the first thing we need to understand when using them is the maintenance of the horizontal sterilizer. Let's learn about it together.


The maintenance of a horizontal sterilizer mainly involves daily wiping of the sterilizer door surface and instruments, and cleaning the sterilizer chamber floor at least once a day. Clean the impurities in the sterilizer outlet filter every day to prevent impurities from entering the exhaust pipe during the sterilizer operation. Before daily operation, check if the sterilizer door seal is flat and intact, without any detachment or damage. Check the accuracy of the instrument pointer every day. After the sterilizer stops running, observe whether the temperature gauge and pressure gauge pointers are at the "0" position; observe whether there are any leaks in the steam, water, and other medium pipes and valves; observe whether various operating indicators of the sterilizer are intact; if any of the above components have problems, do not use the sterilizer; it can only be used after maintenance and repair.


Clean the exterior of the sterilizing device of the horizontal sterilizer once per quarter to prevent dust accumulation and shorten the service life of the air filter. Avoid contact of components with water. Once the water is dry, you can turn on the power. Check the connected sockets and connectors for looseness every quarter; if loose, tighten them. Clean the surface of the safety valve of the horizontal sterilizer every 6 months. Check and clean the steam pipe filter weekly and record the results. The sterilizer should be inspected annually, and the safety valve, pressure gauge, and thermometer should be checked at least once a year, and the inspection results should be recorded and kept. The air filter should be replaced regularly. The choice of water for the sterilizer is also important. If the water quality does not meet the requirements, scaling and corrosion may occur, affecting the sterilization effect and service life. It is recommended to use soft water or pure water with a hardness of 0.7~2.0 mmol/l. The used water should be filtered to keep the horizontal sterilizer clean.


The sterile retention time is related to the packaging. How long an item remains sterile after sterilization depends on its packaging material. If exposed, use immediately; if cloth-wrapped, it can be stored for 7-14 days; hard containers can be kept dry for half a year. However, if there is a wet bag after sterilization, it is considered an invalid bag. The horizontal sterilizer should be operated in good condition and should be regularly maintained by a dedicated maintenance personnel or personnel familiar with the business to ensure normal operation and avoid accidents.


The above article content tells you the basic information of the product. I wonder if you understand it. If you don't understand, please read it quickly. Okay, that's all for today's knowledge points. I hope it can help you.