Summary: Sterilization of medical devices is one of the most important processes in healthcare. It eliminates all living microorganisms, including bacteria, spores, viruses, and fungi, from medical and dental equipment, ensuring their safety and reusability. While various sterilization methods exist, hydrogen peroxide is widely used in medical centers, hospitals, and dental clinics due to its effectiveness, safety, and low cost. Below, we will explore two sterilization techniques using hydrogen peroxide and how to select the right pressure sensor for sterilization equipment based on sensor technical parameters and operational characteristics.
Sterilization of medical equipment is one of the most important processes in healthcare. It eliminates all living microorganisms on medical and dental equipment, including bacteria, spores, viruses, and fungi, ensuring the safety and reusability of these devices. While various sterilization methods exist, hydrogen peroxide is the most widely used in medical centers, hospitals, and dental clinics due to its effectiveness, safety, and affordability. Below, we explore two hydrogen peroxide sterilization techniques and how to select the right pressure sensor for sterilization equipment based on sensor technical parameters and operational characteristics.
Two distinct sterilization processes utilize hydrogen peroxide. Each requires different measurement equipment to ensure proper operation. The first process, plasma sterilization, uses a capacitive vacuum pressure gauge to measure process pressure within the sterilization cycle. Medical equipment, including scalpels and catheters, dental instruments, and other devices with grooves and channels, are inserted into the sterilizer chamber. The chamber is then sealed and evacuated to create a vacuum. Hydrogen peroxide sterilant from a pre-packaged canister is injected into the chamber. The sterilant vaporizes and interacts with the surfaces of the medical/dental equipment, causing a pressure increase; the pressure then decreases again, creating plasma. Hydrogen peroxide free radicals interact with and kill microorganisms. Afterward, the hydrogen peroxide decomposes, leaving only water vapor and oxygen. Medical devices can be used immediately or stored after sterilization.
To ensure effective sterilization, a specific base pressure is needed inside the sterilizer chamber when plasma is generated. A capacitive vacuum pressure gauge is installed on the sterilizer to monitor and/or control chamber pressure, maintaining appropriate pressure throughout the sterilization process. When selecting a vacuum pressure gauge for your application, partner with a supplier offering a range of such products: various full-scale pressure ranges from 10 to 1000 Torr, read accuracy of ±0.5% (preferably ±0.25% option), and a negligible temperature coefficient within a temperature compensation range of 0°C to 50°C.
The second sterilization process uses vaporized hydrogen peroxide, stored in liquid form in a reservoir before being converted to vapor within the sterilization chamber. During operation, the liquid sterilant from the reservoir is sprayed into the system, killing microorganisms on the equipment. This application uses a gauge pressure sensor to measure the pressure the liquid sterilant exerts on it, indicating the hydrogen peroxide level.
This sterilization process works as follows: The pressure sensor is installed at the bottom of the sterilant reservoir. The weight of the sterilant causes pressure on the sensor. The cable on the back of the sensor contains a vent, allowing the sensor to measure pressure relative to local atmospheric pressure (gauge measurement). As the sterilant is consumed, the weight (pressure) decreases, and the output signal sent by the sensor to the redundant monitoring system decreases accordingly. The sensor then alerts the sterilization technician to a low reservoir level. When the sensor register value is 0 PSIG, the reservoir is empty.