+86-519-82422994
Contact Us
Products
Support
Media
About Us
中文
Company News
Industry News
File Download
2022.02.12
The development of portable sterilizers in the medical field
With the development of biotechnology and medicine, the number of medical devices is increasing, and the design is becoming more sophisticated. More and more new technologies and materials are constantly being used in the medical field for surgical and clinical techniques. No matter what sterilization method is chosen, environmental safety, machine safety, and patient safety can be ensured. No matter what type of portable sterilizer you choose, each has its own advantages and disadvantages.
2022.02.06
Only by choosing the right hand-held sterilizer can it play a huge role
To ensure the safety of medical personnel during use, medical masks require strict control from production materials to the production process. Sterilization is an important part of this. Different sterilizers should be selected for different items to improve the effectiveness of portable sterilizers. The safe use and medical quality of portable sterilizers in the medical field vary. Now let's take a look at the different types of sterilizers.
2022.01.31
Ultrasonic cleaner manufacturer: Introduction to ultrasonic cleaners
People hear sound waves with frequencies of 20-20000Hz. Sound waves above 20000Hz are called ultrasonic waves. Sound waves propagate longitudinally according to a sine curve, i.e., alternately strong and weak, and are transmitted successively. When weak sound wave signals act on a liquid, they produce a certain negative pressure on the liquid, i.e., the volume of the liquid increases, and the molecular gaps in the liquid increase, forming many tiny bubbles. When strong sound wave signals act on a liquid, they produce a certain positive pressure on the liquid, i.e., the volume of the liquid is compressed and reduced, and the tiny bubbles formed in the liquid are crushed. Studies have shown that ultrasonic waves acting on liquids
2022.01.25
Ultrasonic cleaner manufacturer: A brief introduction to ultrasonic cleaners
Ultrasound propagates in liquids, causing the liquid and cleaning tank to vibrate together at the ultrasonic frequency. When the liquid and cleaning tank vibrate, they have their own natural frequency, which is the frequency of the sound wave, so people hear a humming sound. With the continuous development of the cleaning industry, more and more industries and enterprises have applied ultrasonic cleaning machines.
2021.11.19
The working principle of the sterilization process in a medical sterilizer
The sterilization process works as follows: A pressure sensor is installed at the bottom of the sterilizer tank. The weight of the sterilizer causes pressure on the sensor. The cable on the back of the sensor contains a vent tube, allowing the sensor to measure the pressure relative to local atmospheric pressure (gauge pressure measurement). As the sterilizer is consumed, the weight (pressure) decreases, and the output signal sent by the sensor to the redundant monitoring system also decreases accordingly. The sensor can then issue a low tank level warning to the sterilization technician. When the sensor register value is 0 PSIG, it indicates that the tank is empty.
The sterilization process of the medical sterilizer uses vaporized hydrogen peroxide
The second sterilization process uses vaporized hydrogen peroxide. Before being converted to steam in the sterilization chamber, this hydrogen peroxide is stored as a liquid in a reservoir. During use, the liquid sterilant is sprayed from the reservoir into the system to kill microorganisms on the equipment. This application uses a pressure sensor to measure the pressure exerted by the liquid in the sterilant reservoir on the pressure sensor itself, thus indicating the hydrogen peroxide level.
Effective sterilization process of medical sterilizer
To this end, a capacitive vacuum pressure gauge is installed on the sterilizer to monitor and/or control chamber pressure and ensure proper pressure is maintained throughout the sterilization process. When selecting a vacuum pressure gauge suitable for your application, work with a supplier that offers a range of such products: with different full-scale pressure ranges from 10 to 1000 Torr, a reading accuracy of +/- 0.5% (or +/- 0.25% if available), and a negligible temperature coefficient within the temperature compensation range of 0℃ to 50℃.
There are two different disinfection processes for sterilization using hydrogen peroxide.
Each requires different measuring equipment to ensure proper operation. The first sterilization process is plasma sterilization using a capacitive vacuum pressure gauge to measure the process pressure in the sterilization cycle. Medical devices are inserted into the sterilizer chamber. Medical devices include scalpels and catheters, dental equipment, and other equipment with grooves and channels.
Accuracy and uniformity of steam sterilizer temperature
The high-pressure steam sterilizer has an overheat protection system, a dry-burn protection system, overpressure protection, a lid closure check system, a leakage protection device, overcurrent and short-circuit protection, and anti-scalding safety protection, etc. These safety protection features of the high-pressure steam sterilizer effectively ensure the safety of the operator.
Safety performance of high-pressure steam sterilizers
Accuracy refers to the deviation between the internal temperature of the sterilization chamber and the set temperature; uniformity refers to the temperature deviation between the top, bottom, left, and right inside the sterilization chamber. Sterilizers with poor accuracy and uniformity can lead to incomplete sterilization or damage to precision instruments in the autoclave.
2021.05.08
Jiangsu Dengguan Medical Device Co., Ltd.
Our main products include: pulse vacuum sterilizers, culture medium sterilizers, water bath sterilizers, ampoule leak detection sterilizers, water bath leak detection sterilizers, pure steam sterilizers, multifunctional Chinese patent medicine sterilizers, rapid cooling sterilizers, vertical steam sterilizers, desktop steam sterilizers, and portable steam sterilizers. These are widely used in medical and health institutions, university and college laboratories, clinical institutions, biological research, food and chemical industries, pharmaceutical factories, and other fields.
Application of pressure sensors in pressure measurement of medical sterilizers
Sterilization of medical devices is one of the most important processes in healthcare. It eliminates all living microorganisms, including bacteria, spores, viruses, and fungi, from medical and dental equipment, ensuring their safety and reusability. While various sterilization methods exist, hydrogen peroxide is widely used in medical centers, hospitals, and dental clinics due to its effectiveness, safety, and low cost. Below, we will explore two sterilization techniques using hydrogen peroxide and how to select the right pressure sensor for sterilization equipment based on sensor technical parameters and operational characteristics.