+86-519-82422994
Contact Us
Products
Support
Media
About Us
中文
Company News
Industry News
File Download
2022.07.22
Precautions for cleaning and using a desktop sterilizer
Before using a desktop sterilizer, clean the machine to be sterilized to prevent residual materials in the desktop sterilizer from damaging the machine itself. Below, we will look at the precautions for cleaning before using a desktop sterilizer and during use.
2022.07.12
Initial inspection of desktop sterilizer and factors affecting the sterilization effect of desktop sterilizer
Benchtop sterilizers are widely used in medical applications; their primary function is sterilization. When using a sterilizer for the first time, a preliminary inspection is necessary to prevent operational errors. Below, we will examine the initial inspection of a benchtop sterilizer and the factors influencing its sterilization effectiveness.
2022.07.04
Methods for calibrating the temperature and pressure of a desktop sterilizer
The principle of a tabletop sterilizer is that in a sealed steamer, steam cannot escape, and the pressure continuously rises, causing the boiling point of water to continuously increase, and the temperature inside the pot to increase accordingly. At a pressure of 0.1 MPa, the temperature inside the pot reaches 121 ℃. At this steam temperature, various bacteria and their highly heat-resistant principles can be quickly killed.
2022.06.22
Autoclave manufacturers introduce basic knowledge about autoclaves
Over time, a large number of surgical instrument packs, fabric dressing packs, and cavity instruments such as bone marrow puncture needles appeared. It was found that simply exhausting the cold air from the sterilizer was insufficient, as there was residual cold air and wet packs in the cavity instruments clinically. Therefore, some people began to explore installing vacuum pumps on sterilizers to improve the efficiency of removing cold air inside the sterilizer and to solve the problem of wet packaging. Finally, in the early 1970s, the 2.0 version of the pressure steam sterilizer was introduced, replacing the gravity displacement pressure steam sterilizer, and was named the prevacuum pressure steam sterilizer. Its characteristic is that before the sterilizer enters the sterilization procedure, there is low pressure (negative
2022.06.13
What precautions should be taken when using a horizontal sterilizer? How should daily maintenance be performed?
Horizontal autoclaves are widely used and reliable. The principle of a horizontal autoclave is mainly to denature biological molecules such as proteins. When high-temperature and high-pressure steam comes into full contact with the items to be sterilized, latent heat is released, thus heating the items to be sterilized. Heating accelerates the movement of protein molecules, causing them to collide with each other, which can break the secondary bonds connecting the peptide chains, causing the molecules to change from an orderly and compact structure to a disordered and loose structure. A large number of hydrophobic groups are exposed on the molecular surface, combining with each other to form larger polymers, which solidify and precipitate. The horizontal autoclave irreversibly destroys enzymes and structural proteins, thus killing microorganisms and sterilizing items.
2022.06.06
What are the key knowledge points about horizontal sterilizers?
What is the outline of the relevant knowledge about horizontal sterilizers? I. Principles and Scope of Application Horizontal sterilizers use saturated steam sterilization. When steam condenses, a large amount of latent heat is released, placing the sterilized items in a high-temperature and humid state. After a certain period of time, all bacteria and spores are destroyed, achieving the purpose of sterilization. Widely used in medical, food, pharmaceutical industries and scientific research institutions. Sterilizing surgical instruments, dressings, drugs, culture media, food, etc.
2022.05.31
How to operate a horizontal sterilizer?
Before installation and use, the horizontal sterilizer should be registered with the local special equipment supervision agency. Operators of the horizontal sterilizer must undergo specialized training, be familiar with the operating system, and strictly abide by the operating procedures during operation. Horizontal sterilizers are a type of pressure vessel, and exceeding the pressure limit is strictly prohibited. For specific data on the horizontal sterilizer, please refer to the equipment's quality certificate. Before using the horizontal sterilizer, check that all instruments are functioning normally, the power supply is correct and functioning, the backup valves are closed, the water must be added above the high water level line before operation, and the sterilization temperature and time must be set.
2022.05.25
The following describes the maintenance of an autoclave.
The quality of the autoclave affects the quality of food and should be taken seriously. Sterilization is the first step in food processing to ensure food safety, and the quality of sterilization directly affects the quality of food. As a primary branch of special equipment, autoclaves are mainly affected by the growth rate of the national economy and the scale of fixed asset investment, and have a certain business cycle. Autoclaves are widely used in pharmaceutical companies, food companies, medical institutions, laboratories, etc. The occupation has no significant regional or seasonal characteristics.
2022.05.19
Below, I will explain the principle and cleaning method of a sterilizer.
Sterilizer principle: During sterilization, sterilizing water enters the sterilizer tank from the bottom. At this time, the temperature inside the sterilizer is at room temperature. When hot water enters the sterilizer through the pipe, it first contacts the 304 stainless steel, and the temperature of the hot water will decrease. When it contacts the product, the temperature will decrease further, thus prolonging the heating time of the product and alleviating the change process. As hot water gradually enters the sterilizer from the bottom, the water level in the sterilizer gradually rises. The part of the hot water that first contacts the product on the water surface continues to contact the product, and the temperature will gradually decrease, thus slowing down the heating speed of the product and preventing the outer packaging edges from wrinkling.
2022.05.13
Below is a guide on how to use an autoclave.
Autoclave Usage: 1. Adding Water: First close the drain valve, adjust the main valve to "full drainage", then open the water inlet valve and add distilled water to the steam generator. When the water level is about 1-2 cm from the top of the water gauge, close the water inlet valve and set the main valve to "off".
2022.05.07
Below, I will explain the characteristics of a sterilizer.
Below is an explanation of the characteristics of a sterilizer: In the high-temperature sterilization process of food, the main target of sterilization is Clostridium botulinum, which produces toxins that can cause fatal harm to the human body. It is a heat-resistant anaerobic bacterium. At 121℃ for three minutes, or around 100℃ for six hours, it will lose its biological activity. Of course, the higher the temperature, the shorter the survival time of the pathogen. According to scientific experiments, 121℃ sterilization is advisable. At this temperature, the packaging has good heat resistance, and the food tastes good. When sterilizing at 121℃, the F value of the food center reaches 4, and no Clostridium botulinum will be detected in the food, meeting the requirements of commercial sterility. Therefore, we sterilize meat products.
2022.05.01
Handheld sterilizer manufacturer: Important considerations for autoclave operation
A high-pressure steam sterilizer is a device that uses saturated high-pressure steam to sterilize products quickly and reliably. It uses continuous heating to help the water in the sterilizer boil, producing steam. The steam enters the pot, increasing internal pressure and raising the boiling point to a high level, achieving high temperatures. It mainly consists of a sealable drum, pressure gauge, exhaust valve, safety valve, and electric heating wire. It is suitable for sterilizing food, pharmaceuticals, culture media, surgical instruments, dressings, glassware, rubber products, etc., in food, medical, and research units. It is a commonly used sterilization method in microbiology experiments.